Rainbow Power-Supply

         The product spectrum of the company covers the power rating from 5W to 2,000W in
over 2,000 different models.

Rain Proof Power Supply

Features:

Rainproof Design, Accord with IP21

CV-200RC-SERIES

CV-200RC-SERIES

Special Aluminum Case, Excellent

heat-dissipating, High reliability

Protections: Over Load/Short Circuit

100% full load burn-in test

1 years warranty

Size: 219x102x49mm

AC input voltage range…………………………176-264VAC

Input frequency……………………………………47-63Hz

AC inrush current…………………………………Cold start, 60A/ 230VAC

Line regulation(full load)………………………..±1%

Output over load protection……………………hiccup mode, auto-recovery

Rise, hold up time………………………………..100mS, 10mS at full load

Withstand voltage…………………………………I/P-O/P, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC

Working temperature…………………………….-20~+60℃@(refer to temperature derating curve)

Storage temperature……………………………..-40℃~+85℃@100%  20%~95%RH (non condensing)

Safety standards……………………………………GB4943, UL60950-1, EN60950-1

EMC standards……………………………………..GB9254, EN55022 class A

Cooling method……………………………………..Forced air cooling by Built-in DC fan

Product model DC output Load regul. R&N Efficiency
CV-200RC-12 12V,0~16.6A ±1% 300mV 85%
CV-200RC-24 24V,0~8.3A ±1% 300mV 87%
CV-200RC-36 36V,0~5.6A ±1% 300mV 88%
CV-200RC-48 48V,0~4.2A ±1% 400mV 88%

Features:

Rainproof Design, Accord with IP21

CV-250RC-SERIES

CV-250RC-SERIES

Special Aluminum Case ,Excellent

heat-dissipating, High reliability

Protections: Over Load/Short Circuit

100% full load burn-in test

1 years warranty

Size: 219x102x49mm

AC input voltage range…………………………176-264VAC

Input frequency…………………………………….47-63Hz

AC inrush current………………………………….Cold start, 60A/ 230VAC

Line regulation(full load)…………………………±1%

Output over load protection…………………….hiccup mode, auto-recovery

Rise, hold up time…………………………………100mS, 10mS at full load

Withstand voltage………………………………….I/P-O/P, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC

Working temperature……………………………..-20~+60℃@(refer to temperature derating curve)

Storage temperature………………………………-40℃~+85℃@100%  20%~95%RH (non condensing)

Safety standards…………………………………….GB4943, UL60950-1, EN60950-1

EMC standards………………………………………GB9254, EN55022 class A

Cooling method………………………………………Forced air cooling by Built-in DC fan

Product model DC output Load regul. R&N Efficiency
CV-250RC-12 12V,0~21A ±1% 300mV 85%
CV-250RC-24 24V,0~10.5A ±1% 300mV 87%
CV-250RC-36 36V,0~7A ±1% 300mV 88%
CV-250RC-48 48V,0~5 .2A ±1% 400mV 88%

Features:

Rainproof Design, Accord with IP21

Power-Supply

CV-400RD

Special Aluminum Case, Excellent

heat-dissipating, High reliability

Protections: Over Load/Short Circuit

100% full load burn-in test

1 years warranty

Size: 224x124x60mm

AC input voltage range………………………..176-264VAC

Input frequency…………………………………..47-63Hz

AC inrush current………………………………..Cold start, 60A/ 230VAC

Line regulation(full load)………………………±1%

Output over load protection…………………..hiccup mode, auto-recovery

Rise, hold up time……………………………….100mS, 10mS at full load

Withstand voltage………………………………..I/P-O/P, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC

Working temperature…………………………..-20~+60℃@(refer to temperature derating curve)

Storage temperature……………………………-40℃~+85℃@100%  20%~95%RH (non condensing)

Safety standards…………………………………GB4943, UL60950-1, EN60950-1

EMC standards…………………………………..GB9254, EN55022 class A

Cooling method…………………………………..Forced air cooling by Built-in DC fan

Product model DC output Load regul. R&N Efficiency
CV-400RD-12 12V,0~33A ±1% 150mV 83%
CV-400RD-24 24V,0~16.6A ±1% 200mV 85%
CV-400RD-36 36V,0~11A ±1% 300mV 86%
CV-400RD-48 48V,0~8.3A ±1% 400mV 86%

Features:

Rainproof Design, Accord with IP21

Power-Supply

CV-400RD

Special Aluminum Case, Excellent

heat-dissipating, High reliability

Protections: Over Load/Short Circuit

100% full load burn-in test

1 years warranty

Size: 224x124x60mm

AC input voltage range………………………..176-264VAC

Input frequency…………………………………..47-63Hz

AC inrush current………………………………..Cold start, 60A/ 230VAC

Line regulation(full load)………………………±1%

Output over load protection…………………..hiccup mode, auto-recovery

Rise, hold up time……………………………….100mS, 10mS at full load

Withstand voltage………………………………..I/P-O/P, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC

Working temperature…………………………..-20~+60℃@(refer to temperature derating curve)

Storage temperature……………………………-40℃~+85℃@100%  20%~95%RH (non condensing)

Safety standards…………………………………GB4943, UL60950-1, EN60950-1

EMC standards…………………………………..GB9254, EN55022 class A

Cooling method…………………………………..Forced air cooling by Built-in DC fan

Product model DC output Load regul. R&N Efficiency
CV-400RD-12 12V,0~33A ±1% 150mV 83%
CV-400RD-24 24V,0~16.6A ±1% 200mV 85%
CV-400RD-36 36V,0~11A ±1% 300mV 86%
CV-400RD-48 48V,0~8.3A ±1% 400mV 86%

Features:

 

Product model Specification Note Note
CV-250RC-12 136x70x42 Stander Rain proof design

Features:

Product model Specification Note Note
CV-250RC-12 182x59x34 Stander Full Water proof

Features:

Product model Specification Note Note
CV-250RC-12 219x74x46 Stander Full Water proof

Indoor Power Supply

Features:

Low Cost,High reliability, Built-in EMI filter Low output ripple & noise

A-200-series

A-200-series

Approved: CE, CCC BIS

Protections:Over load/Short circuit

100%Full load aging

2 year warranty

size:199X110X50mm

Low Cost,High reliability, Built-in EMI filter Low output ripple & noise

Approved: CE, CCC BIS

AC input voltage range/Input frequency 88-132VAC/176~264VAC/47~63HZ Selected by switch
AC inrush current Cold start,40A/230VAC
Line regulation(full load) ≤0.5%
Output over load protection 110%-150%hiccup mode,auto-recovery
Rise,hold up time 50ms,20msat full load(typical)
Withstand voltage I/P-O/P:3KVAC,  I/P-FG:1.5KVAC, O/P-FG:0.5KVAC,1min
Working temperature -30℃~+60℃
Storage temperature -40℃~+100℃,20~95%RH(non condensing)
Safety standards GB4943, UL60950-1,EN60950-1
EMCstandards GB9254,EN55022 class A
Cooling method Free air cooling convection
Product model DC output Load regul R&N Efficiency
A-200-5 5V,40A ±2% 100mV ≥78%
A-200-12 12V,16.7A ±1% 120mV ≥80%
A-200-24 24V,8.3A ±1% 200mV ≥83%

Features:

Low cost, high reliability

A-60-SERIES

A-60-SERIES

Built-in EMI Filter

Low output ripple&noise

Protections: Over load/ Short circuit

1 year  warranty

Case: 806  Size: 159*98*42mm

AC Input voltage range……………………………..176-264VAC

Input frequency…………………………………………47-63Hz

AC Inrush current………………………………………Cold start, 40A/ 230VAC

DC adjustment range………………………………. ±10% rated output voltage

Line regulation(full load)……………………..≤0.5%

Output over load protection………………………..110%-150% hiccup mode, auto-recovery

Rise, hold up time……………………………………..50mS, 20mS at full load (typical)

Withstand voltage……………………………………..I/P-O/P, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC,1 min

Working temperature………………………………..-10℃ to + 40℃@100%, +60℃@ 60% load

Storage temperature…………………………………-20℃~ +85℃,20%~ 95%RH (non-condensing)

Safety standards……………………………………….Design refer to GB4943,UL60950-1,EN60950-1

EMC standards…………………………………………Design refer to GB9254,EN55022 class A

Cooling method…………………………………………Free air cooling convection

Product model DC output Load regul. R&N Efficiency
A-60–3.3 3.3V,12A 2% 100mV 69%
A-60-5 5V,12A 2% 100mV 72%
A-60-7.5 7.5V,8A 1% 100mV 74%
A-60-12 12V, 5A 1% 120mV 77%
A-60-13.8 13.8V,4.4A 1% 120mV 77%
A-60-15 15V,4A 1% 150mV 78%
A-60-24 24V,2.5A 1% 200mV 80%
A-60-48 48V,1.3A 1% 240mV 82%

Features:

A-200NM-Series

A-200NM-Series

Low cost,high reliability, Built-in EMI filter Low output ripple & noise

Low output ripple & noise

Protections:Over load/Short circuit

100%Full load aging

2 year warranty

size:199X110X50mm

AC input voltage range/Input frequency 88-132VAC/176~264VAC/47~63HZ Selected by switch
AC inrush current Cold start,40A/230VAC
Line regulation(full load) ≤0.5%
Output over load protection 110%-150%hiccup mode,auto-recovery
Rise,hold up time 50ms,20msat full load(typical)
Withstand voltage I/P-O/P:3KVAC,  I/P-FG:1.5KVAC, O/P-FG:0.5KVAC,1min
Working temperature -30℃~+60℃
Storage temperature -40℃~+100℃,20~95%RH(non condensing)
Safety standards GB4943, UL60950-1,EN60950-1
EMCstandards GB9254,EN55022 class A
Cooling method Free air cooling convection
Product model DC output Load regul R&N Efficiency
A-200NM-5 5V,40A ±2% 100mV ≥78%
A-200NM-5D 5V,40A ±2% 100mV ≥78%

Features:

A-300AY-5

A-300AY-5

Low cost, high reliability

Built-in EMI Filter

Low output ripple&noise

Protections: Over load/ Short circuit

1 year  warranty

Product model Specification Note Note
A-300AY-5 217x117x30 350W, 5V, 70A Slim With Fan

Outdoor Power Supply

Features:

A-350AA-SERIES

A-350AA-SERIES

Low profile,l ess weight
High reliability,strong load capability
Protections: Overload/Short circuit
100% pass full load high temp aging test
1 year warranty
Size: 218×117×30mm

AC Input Voltage Range/Input Frequency……………………………………………………………………………………200~240VAC/47~63Hz

AC Inrush Current……………………………………………………………………………………………………………………….cold start,60A/230VAC

Line Regulation(full load)……………….. ……………………………………………………………………………………………………………………….. ±1%

Output Overload Protection…………………………………………………………………………………110%-150% Hiccup mode,auto-recover

Rise,Hold up time…………………………………………………………………………………………………………………….. 100mS, 10mS at full load

Withstand Voltage……………………………………………………………………..I/P-O/P:3KVAC,I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC,1 min

Working temperature…………………………………………………………………………….-30℃~+60℃(refer to temperature derating curve)

Storage Temperature……………………………………………………………………………….. -40℃~+100℃,20~95%RH( non-condensing)

Safety Standards……………………………………………………………………………………………………………..GB4943, UL60950-1, EN60950-1

EMC Standards……………………………………………………………………………………………………………………….. GB9254, EN55022 class A

Cooling Method…………………………………………………………………………………………………………….Forced air cooling by built-in DC fan

Model No DC output        Tol R&N Effi.
     A-350AA-2.8 2.8V,0~70A  ±2% 150mV 76%
     A-350AA-3.3 3.3V, 0~70A  ±2% 150mV 76%
     A-350AA-3.8 3.8V,0~70A  ±2% 150mV 78%
     A-350AA-4.2 4.2V,0~70A  ±2% 150mV 80%
     A-350AA-5 5V, 0~70A  ±2% 150mV 82%

Features:

A-400-SERIES

A-400-SERIES

Low cost, high reliability

Built-in EMI Filter

Low output ripple&noise

Protections: Over load/ Short circuit

Forced air cooling by built-in DC fan

1 year  warranty

Case: 812  Size: 260*102*65mm

AC Input voltage range…………………………………..176-264VAC

Input frequency…………………………………………47-63Hz

AC Inrush current……………………………………….Cold start, 60A/ 230VAC

DC adjustment range……………………………………..±10% rated output voltage

Line regulation(full load)………………………………..≤0.5%

Output over load protection……………………………….110%-150% shut off, AC recycle to re-start

Rise, hold up time……………………………………….50mS, 20mS at full load (typical)

Withstand voltage………………………………………..I/P-O/P, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC,1 min

Working temperature………………………………………-10℃ to + 40℃@100%, +60℃@ 60% load

Storage temperature………………………………………-20℃~ +85℃,20%~ 95%RH (non-condensing)

Safety standards…………………………………………Design refer to GB4943,UL60950-1,EN60950-1

EMC standards……………………………………………Design refer to GB9254,EN55022 class A

Cooling method…………………………………………..Forced air cooling by built-in DC fan

Product model DC output Load regul. R&N Efficiency
A-400-12 12V,33A 1% 120mV 80%
A-400-13.8 13.8V,29A 1% 120mV 80%
A-400-15 15V,26.7A 1% 150mV 81%
A-400-24 24V,16.7A 1% 200mV 82%
A-400-48 48V,8.3.A 1% 240mV 84%

Features:

A-500 SERIES

A-500 SERIES

Low cost, high reliability

Built-in EMI Filter

Low output ripple&noise

Protections: Over load/ Short circuit

Forced air cooling by built-in DC fan

1 year  warranty

Case: 814 Size: 241*124*65mm

AC Input voltage range…………………………………..180-260VAC

Input frequency………………………………………….47-63Hz

AC Inrush current………………………………………..Cold start, 60A/ 230VAC

DC adjustment range………………………………………±≤10% rated output voltage

Line regulation(full load)…………………………………≤0.5%

Output over load protection………………………………..110%-150% shut off, AC recycle to re-start

Rise, hold up time………………………………………..50mS, 20mS at full load (typical)

Withstand voltage………………………………………….I/P-O/P, I/P-FG: 1.5KVAC, O/P-FG: 0.5KVAC,1 min

Working temperature……………………………………….-10℃ to + 40℃@100%, +60℃@ 60% load

Storage temperature……………………………………….-20℃~ +85℃,20%~ 95%RH (non-condensing)

Safety standards………………………………………….Design refer to GB4943,UL60950-1,EN60950-1

EMC standards…………………………………………….Design refer to GB9254,EN55022 class A

Cooling method……………………………………………Forced air cooling by built-in DC fan

Product model DC output Load regul. R&N Efficiency
A-500-5 5V,80A 2% 150mV 78%
A-500-7.5 7.5V,60A 1% 150mV 80%
A-500-12 12V,40A 1% 150mV 83%
A-500-13.8 13.8V,35A 1% 150mV 83%
A-500-15 15V,33A 1% 150mV 84%
A-500-24 24V,20A 1% 200mV 85%
A-500-48 48V,10A 1% 240mV 86%